Maxim-integrated 78M6631 User Manual

Browse online or download User Manual for Hardware Maxim-integrated 78M6631. Maxim Integrated 78M6631 User Manual

  • Download
  • Add to my manuals
  • Print

Summary of Contents

Page 1 - 78M6631

AVAILABLE USER GUIDE 78M6631 Firmware Description Document October 10, 2011 Rev 2 UG_6631_078

Page 2 - XXXX Maxim Integrated

78M6631 Firmware Description Document UG_6631_078 10 Rev 2 2.2.4 Active, Reactive and Apparent Power Calculation Figure 5 shows the signal pro

Page 3 - Table of Contents

UG_6631_078 78M6631 Firmware Description Document Rev 2 11 2.2.5 Voltage and Current Harmonics and Fundamental Measurement The 78M6631 firmware

Page 4

78M6631 Firmware Description Document UG_6631_078 12 Rev 2 2.2.7 Power Factor Calculation The 78M6631 provides a direct power factor measureme

Page 5 - 1 Introduction

UG_6631_078 78M6631 Firmware Description Document Rev 2 13 2.2.11 Sine and Cosine Reference An internal Sine/Cosine oscillator generates wavefor

Page 6

78M6631 Firmware Description Document UG_6631_078 14 Rev 2 2.3 Configuration and Control 2.3.1 Input Registers The following parameters are c

Page 7 - 2 Functional Description

UG_6631_078 78M6631 Firmware Description Document Rev 2 15 2.3.5 Calibration As with any measurement system, there are also multiple sets of coe

Page 8

78M6631 Firmware Description Document UG_6631_078 16 Rev 2 To calibrate the voltage and current the following steps are required: • AC Source

Page 9

UG_6631_078 78M6631 Firmware Description Document Rev 2 17 3 Serial Peripheral Interface (SPI) The 78M6631 has an on-chip SPI interface. The int

Page 10

78M6631 Firmware Description Document UG_6631_078 18 Rev 2 4 Serial Communication and CLI The serial communication with the 78M6631 takes plac

Page 11

UG_6631_078 78M6631 Firmware Description Document Rev 2 19 5 Register Descriptions All register are 32 bits (4 bytes) and are on ”longword” (4 b

Page 12 - 2.2.9 Accumulation Interval

78M6631 Firmware Description Document UG_6631_078 Maxim Integrated 160 Rio Robles, San Jose, CA 9

Page 13 - 2.2.12 High-Pass Filters

78M6631 Firmware Description Document UG_6631_078 20 Rev 2 5.2 Status Register The status register contains alarms and system status flags tha

Page 14 - 2.3.4 Scaling

UG_6631_078 78M6631 Firmware Description Document Rev 2 21 5.3 Measurement Results Register Output CLI Address (hex) LSB SPI Address (hex) LSB

Page 15 - 2.3.5 Calibration

78M6631 Firmware Description Document UG_6631_078 22 Rev 2 Output Register CLI Address (hex) LSB SPI Address (hex) LSB Comment PFA 15A 568

Page 16 - 2.3.8 Creep Threshold

UG_6631_078 78M6631 Firmware Description Document Rev 2 23 5.3.1 High-Rate Results Registers There is a set of registers that are updated at a h

Page 17 - (From 78M6631)

78M6631 Firmware Description Document UG_6631_078 24 Rev 2 5.4 Parameters Configuration These registers are defined as input registers. The va

Page 18 - 4.1 CLI Interface

UG_6631_078 78M6631 Firmware Description Document Rev 2 25 5.4.4 Digital I/O Configuration Input Register CLI Address (Hex) SPI Address (Hex) Ph

Page 19 - 5 Register Descriptions

78M6631 Firmware Description Document UG_6631_078 26 Rev 2 6 System Connection Diagram Examples This section shows supported 3-phase connectio

Page 20 - 5.2 Status Register

UG_6631_078 78M6631 Firmware Description Document Rev 2 27 3-Phase 4-Wire (Shunt) An alternative to the previous configuration, the following fig

Page 21 - Rev 2 21

78M6631 Firmware Description Document UG_6631_078 28 Rev 2 Non-Isolated Basic Delta Connection (alternative configuration) The system is refere

Page 22

UG_6631_078 78M6631 Firmware Description Document Rev 2 29 7 Command Line Interface (CLI) Description The 78M6631 firmware implements an interfa

Page 23

UG_6631_078 78M6631 Firmware Description Document Rev 2 3 Table of Contents1 Introduction ...

Page 24 - 5.4.2 Alarms Limit Setting

78M6631 Firmware Description Document UG_6631_078 30 Rev 2 7.3.1 Individual Address Read The host can request the information in hex or decima

Page 25

UG_6631_078 78M6631 Firmware Description Document Rev 2 31 7.3.5 Repeat Command The repeat command can be useful for monitoring measurements and

Page 26

78M6631 Firmware Description Document UG_6631_078 32 Rev 2 8 Contact Information For more information about Maxim products or to check the ava

Page 27

78M6631 Firmware Description Document UG_6631_078 4 Rev 2 TablesTable 1: Measurement Equations Definitions ...

Page 28 - LOAD A-B

UG_6631_078 78M6631 Firmware Description Document Rev 2 5 1 Introduction This document describes the 78M6631 firmware (6631_3PH_6S_URT_B21), whi

Page 29 - 7.3 Data Access Commands

78M6631 Firmware Description Document UG_6631_078 6 Rev 2 ABCVCVBVALOAD A-CIAPIANIBPIBNICPICNV3P3AABC78M6631LOAD A-BLOAD B-CD/Y Figure 2. Simpl

Page 30 - 7.3.4 Concatenated Reads

UG_6631_078 78M6631 Firmware Description Document Rev 2 7 2 Functional Description This section summarizes the functional operation of the 78M66

Page 31 - 7.3.5 Repeat Command

78M6631 Firmware Description Document UG_6631_078 8 Rev 2 At the end of each accumulation interval, these measurements are provided to the MPU

Page 32 - 8 Contact Information

UG_6631_078 78M6631 Firmware Description Document Rev 2 9 2.2.3 Voltage and Current RMS Calculation As shown in Figure 4, the voltage and curren

Comments to this Manuals

No comments